Keep An Eye Out | Damaged Three-Ring Retention Loop

Published on Friday, January 26, 2024

Keep An Eye Out | Damaged Three-Ring Retention Loop

Above: Photo by Eddie Phillips.

A jumper noticed this severe damage to the three-ring retention loop on his risers when cleaning his cutaway cables. Closer inspection revealed that the grommet that the loop passes through on the riser was not seated completely, leaving a rough edge exposed. This rough piece of metal sawed into the fabric of the loop when it was under load. It is likely that this damage occurred fairly quickly over the previous few months, since the rig owner inspected his gear regularly, including his risers.

This situation reinforces the wisdom of inspecting your gear regularly and thoroughly between reserve pack jobs. If this component had failed while the skydiver was under canopy (the most likely time for it to happen), it would have released the three-ring system on that side. Close to the ground, the results would have been catastrophic. In addition, the damage occurred on the riser that held the RSL connection, meaning that in a failure, the released reserve would have had to fight for air with the half-attached main. Fortunately, this jumper carefully inspected his gear and caught the issue before it caused problems during a skydive.

Comments (0)Number of views (14972)

Author: USPA Staff

Categories: Safety & Training, Keep An Eye Out

Tags:

Print
AXIS

 

USPA SIS

Donors
Five Minute Call | Jun 01, 2020

Donors

USPA SIS

Seas the Day
Features | May 01, 2020

Seas the Day

The New Normal—Safety Day 2020
Features | May 01, 2020

The New Normal—Safety Day 2020

Non-Fatal Incident Summary
Features | May 01, 2020

Non-Fatal Incident Summary

USPA SIS

Safety Check | Look It Up
Safety Check | May 01, 2020

Safety Check | Look It Up

USPA SIS

First6869707173757677Last